  1. M

    MEP-002a Voltage Issue

    Not sure why
  2. M

    MEP-002a Voltage Issue

    thanks
  3. M

    MEP-002a Voltage Issue

    TM 5-6115-584-12. Change 6 page 2-3 figure 2-2 Reconnection Switch
  4. M

    MEP-002a Voltage Issue

    What would I connect the jumper to? The instructions say from LO to #6 in section G, which I can't find .
  5. M

    MEP-002a Voltage Issue

    William at Delk's said it was not a good idea to run the gen at 120V. He may have been thinking about the possible fault condition. The instructions say run a jumper from LO to #6 in section G. I am unable to find out where this is. As a side note, William passed away near Christmas. He was...
  6. M

    MEP-002a Voltage Issue

    I have a MEP-002a and had it checked out at Delk's. They put it on a load bank and could find no problems with it. When using this generator it goes (240V setting) first into a SMA Smartformer which drops the voltage to 120v and then to a charge controller to charge batteries. When used in this...
  7. M

    Mep002 trailer

    There is a small lever on the tongue near the brake fluid reservoir. It has teeth on it. What does this do? Also I am having problems with the brakes sticking, How can I free them up?
  8. M

    Voltage Problem MEP-002

    Thanks to all!
  9. M

    Hooking up MEP002 to my house

    What to I need to unhook to unbond the generator neutral from the trailer ground?
  10. M

    Voltage Problem MEP-002

    Have a MEP -002. When it's running with a small load (500W), it works fine. voltage is fully adjustable. When I then add a load up to say 50%, the voltage drops to 200V (from 240V), and is no longer adjustable. What could this be? Thanks to all in advance for your help!
  11. M

    Mep002 proper grounding

    When hooking generator to house wiring, do I only ground the trailer to the ground rod? I saw that the ground rod wire should not be hooked to the generator neutral, but that the generator neutral should tie into the house neutral, Is that right?
  12. M

    Connected my MEP-803A the proper way as my home standby generator... Install pics...

    Where is the internal jumper that connects the equipment ground to the neutral? I have my mep002 hooked to my house and may have the neutral and equipment ground bonded.
  13. M

    Voltage issue

    Sometimes when I start my mep002 the voltage drops to about 200v under load. When this happens the voltage adjustment will not raise voltage. If I keep trying and the voltage stays at 240v it works fine. Are their brushes that might need checking?
  14. M

    Rotating diode issue

    Thanks
  15. M

    Rotating diode issue

    I'm using rosin core but I don't know the composition. I tinned both wires and used 150w soldering iron. I soldered the diode with a 30w iron.
  16. M

    Rotating diode issue

    Thanks for the feedback. I checked my solder joint and it is holding. When I start the generator and turn the breaker on sometimes the voltage drops. I can hold the knob on start and reflash the field. Sometimes this will cause the voltage to not fall and it will generate fine. I don't have to...
  17. M

    Rotating diode issue

    In replacing diode I cut wire too short. I soldered a short piece of wire onto diode to make it reach and have tried numerous times to solder two wires together. It will last for a few days (running generator daily) and then come apart. Is there some type of crimp that will last in that...
  18. M

    MEP 002a Generator Diodes

    I believe the 3 diodes on one heat sink are the same and the 3 on the opposing heat sink are reversed polarity.
  19. M

    MEP002a ASK

    How much does the ASK reduce the noise level? Are there any mep002a's in eastern TN with the ASK that I could listen to? How much difference would just a muffler make? Thanks
  20. M

    Best motor oil for MEP-002a

    Thanks for all the answers. That makes me feel okay with using 15W-40 year round.