  1. 155mm

    Wipers not working

    Item 18, center of windshield.
  2. 155mm

    A not-so-funny story (hz)

    Make sure and post how much a civilian load test costs.
  3. 155mm

    Sat 11/11/2017 Pampa Tx Veterans day parade

    I think I am going
  4. 155mm

    003a unstable voltage

    thats what i call service with a smile
  5. 155mm

    Acquired a Military surplus load bank

    Correction, mine isnt a Essex, its a UMC 33kw, like same but different
  6. 155mm

    #3 The smoker, MEP 005A

    No long term plans at this time. Ideas?
  7. 155mm

    #3 The smoker, MEP 005A

    I finally got all the stars and moons to align to get to finally load test The Smoker. I guess there was a birds nest in the muffler because I did look down the pipe and didnt see anything. She needs some more work done.... a hertz gauge and an amps gauge before I really just let her sit there...
  8. 155mm

    Proper generator grounding

    he is about 7 hours ahead of us, so he will fix it when he gets out of bed
  9. 155mm

    mep 806b shuts down!

    Watch this video first, and remember that set is capable of 200 amp from each leg. https://www.youtube.com/watch?v=9iKD7vuq-rY next is the reading and setting up part, and dont skip the ground rod, its the thing that sends the angry pixie's somewhere else, rather than thru your body go get to...
  10. 155mm

    Question about wet stacking

    I fully understand these are two completely different sets, but wetstacking is the same problem in any diesel fired motor and the way to repair it is the same.... load it, heat it up and blow out the cob webs.
  11. 155mm

    Question about wet stacking

    Maybe we need to brainstorm a cheap/junk yard load tester and open source it here
  12. 155mm

    Question about wet stacking

    I have an 005a that probably spent its whole life under a 'less than favorable' condition on a water purification unit, 3300hrs. Here is the thread if you want to read https://www.steelsoldiers.com/showthread.php?164640-3-The-smoker-MEP-005A&highlight= Even under the worst conditions for a...
  13. 155mm

    Question about wet stacking

    I need a button that says 'does not pay attention to detail' Your question is how long is safe under a light load. My uneducated answer is a very long time, because you said you could load 50% and that will help. There needs to be about an hour a day of all the load you can throw at it, even...
  14. 155mm

    Question about wet stacking

    clothes dryer was asked about.
  15. 155mm

    Some Days I Love My Job

    it only happens if there is a video.
  16. 155mm

    It started with a storm... MEP002A

    There is something addictive in CARC paint, its like they put cocaine in the paint or something. I have not met anyone yet that only has 1.
  17. 155mm

    003a unstable voltage

    So has throttle cable been checked to verify the lock/cable are servicable and mounted tight? Also is the return spring still on the IP where the throttle hooks up? After the electrics were repaired, it sounds like the throttle cable is stretched, or the lock isnt locking correctly. Not even...
  18. 155mm

    No-Start Condition

    A diesel only needs 3 things to run: fuel, compression, and air. So you have verified 2 of the 3, air for the air cleaner check, compression for the extra batteries and it cranks, so only thing left is fuel. Purged the metal fuel lines at all 8 of the injectors like you said? It makes a mess...
  19. 155mm

    sales tax exemption issues

    Easiest way to do that, joe snuff buys them from gp, joe snuffy trading post picks up and delivers . I know its a pita, had that problem when the farm (155mm farm) buys equipment from iron planet, so 155mm transporters has to pickup/ deliver and charge 155mm farm with an invoice
  20. 155mm

    MEP-805b starting problems

    Another thing in having to flash the field, try adjusting the crank sensor exactly by the book and see if that fixes the modified start sequence. Dont worry anout holding the start sw in the start position for too long, the starter disengages onits own unless you hear it grinding. Sorry for so...