• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. cranetruck

    XM791 Recoveries

    Thanks for the update! Pls, send more tire pictures (PM perhaps) if you get a chance. The date code on the one posted is probably 49th week of 1977 and it looks like a recap... About the horns, the original was the electric and the air horn was added on an MWO in the early to mid seventies. I...
  2. cranetruck

    XM791 Recoveries

    Agreed. From personal experience with this series of trucks, I just know Oldfart and sons will fall in love with it (them).
  3. cranetruck

    Unknown Vehicle Heater

    I have some info on "Superflex" heater kits models 460 and 461 and they date to the early '50s, run on gasoline and operate on 6VDC. They are for the 1/4 ton trucks...
  4. cranetruck

    MEP018 shorted windings..how?

    No problem here, if things don't fail we don't learn so much from them and I'm getting real comfy with the mep018. :-)
  5. cranetruck

    MEP018 shorted windings..how?

    Started the set 0830 this morning. The good news is that after a field flash, it generated 120/208 VAC, however, just like Peter predicted, there was smoke, less than a minute after the field flash, with the typical smell of melting wire insulation. I shut it down immediately. The thermocouple...
  6. cranetruck

    MEP018 shorted windings..how?

    Thank you Peter and Ike for the heads up on the possibility of heat/smoke... I'll have a thermocouple probe taped to the generator case, so that any radical temp increase can be caught in time. The control box is now rewired for the 120/208 3ph (2 ph?) as shown above. I had everything ready to...
  7. cranetruck

    MEP018 shorted windings..how?

    Thanks guys, and what about current capacity with one less set of windings or doesn't that come into play?
  8. cranetruck

    MEP018 shorted windings..how?

    Alright, so what are the consequences of this modified "120/208V 3 phase" wiring modification? Image below shows the wiring according to the selector switch on top (ideal) and the modified wiring as suggested by Ike with the shorted windings isolated. Power capacity? Is 208VAC harmful to...
  9. cranetruck

    MEP018 shorted windings..how?

    An enlarged portion of the diagram attached. By the wiring diagram, the VR works on 120VAC (same as convenience outlet). I plan on working on this tomorrow. Your help is greatly appreciated!
  10. cranetruck

    MEP018 shorted windings..how?

    Thanks Ike! So I'll end up with this and the VR and the convenience outlet rewired to pic up a new 120 VAC leg (L2 to L0 or L1 to L0).
  11. cranetruck

    MEP018 shorted windings..how?

    The most severe load that the generator has seen during the last 25 hours of operation (since last July) would be the water heater, which is somewhere around 4KW. Don't know what is considered an overload with the "split phase" hook-up. Interesting idea rewiring so that the shorted windings are...
  12. cranetruck

    MEP018 shorted windings..how?

    That's one solution I am hoping for, but need to know how much the connector can be pulled out safely. It's pretty tight and will only come out about 1/2 inch or so and I'm not ready to pull harder without knowing what's inside.
  13. cranetruck

    MEP018 shorted windings..how?

    Having made the unpleasant discovery that my 10KW generator suffer from a short circuit between two of its windings, T2, T5 to T8, T11, I wondering how this can happen. Perhaps some of the electrical heavyweights, Isac, Speedemon and others can help explain. This equipment is extremely well...
  14. cranetruck

    MEP018 TM wiring/test inconsistency

    Thanks Bob, much appreciated. Again, I see the error in my ways of doing things (not looking at the details or overlooking the obvious), the pin numbers in Fig 8-7 refer to the J4 connector on the generator head NOT the connector at the control box end. It should be labeled J4 or P4 while the...
  15. cranetruck

    MEP018 TM wiring/test inconsistency

    Yes, thanks, it may be a helpful confirmation of my readings. On my set, the windings terminated on pins 2, 5, 8 and 12 are all shorted and should be two separate non-connected windings if I read the TMs right at all. My previous posts on this subject are under the heading "MEP018 Field Flash...
  16. cranetruck

    MEP018 TM wiring/test inconsistency

    Starting to work on my shorted stator winding problem, I'd like to point out that there is a problem with the suggested continuity test with what's shown in the diagrams. The procedure according to TM 5-6115-275-35 wants you to test for continuity between pins 3 to 6, 8 to 12, 7 to 10, 1 to 4...
  17. cranetruck

    MEP018 Field Flash question

    Checked the windings of the generator and it appears that I have a short between two of them, the ones terminated via (J1) pins 2, 5, 8 and 12 are shorted... Not good, will be difficult to work on, probably best to look for a new generator head, so if anybody is parting out a MEP018, let me know.
  18. cranetruck

    How do i make this crane work what pto?

    Check on the requirements for the pump before you get too far, my crane needs about 15 plus Hp to operate, too much for a belt driven pump IMHO. Also 10 GPH @3,000 psi continuous duty. Call Clark Truck Parts ((304)-755-8811) in Poca, WV for parts, they probably have what you need.
  19. cranetruck

    MEP018 Field Flash question

    Well, I installed the control box and fired up the engine and with a known good wiring it does the same thing as before, bog down the engine when the field flash is engaged...guess the damage was already done. Next I'll be checking the generator windings for shorts and continuity... Taking a...
  20. cranetruck

    MEP018 Field Flash question

    To recap, the unit was running well racking up some 25 hours since last Summer and after sitting for a couple of weeks in December, it barely started, ran terribly (low rpm) so I shut it down. In a separate thread I show how one of the cylinders was replaced on the 4A084 engine and it now starts...
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!

I've Disabled AdBlock
No Thanks