Bring two phases plus a neutral and ground from the generator and connect them as you would any other power source. I recommend looking at the schematic and see which two phases the VR senses from and...
In the spirit of full disclosure I am married to a Chinese woman. She has been wanting to show me around China for a long time. I'm finally taking a real vacation from work to do it.
Culture shock is a real thing. Many things that are normal here would not work in the US or Europe.
I'm...
You are on the right track. Its the phase relationship between the legs that accounts for the difference in voltage on the high voltage side. When two 120v phases are exactly opposite (180 degree out of phase) the math is simple meaning they are additive (technically we would use the same math...
Question 1 - Yes you can do that BUT you have to put a 30a overload ahead of anything rated for 30a (wire, connectors, outlets, etc). That means if you want to connect a 30a circuit to your 60a output you need to add a 30a breaker to be safe and compliant. Edit - You'll need to use a 30a 3 phase...
In my opinion people put too much effort into load balancing these sets when they are being used in emergency situations. As an example are you going to run the dryer much during an outrage?
Look at the loads you are most likely to use simultaneously and see if you can spread them around the...
+1 on the overload. You will need every ounce of energy that an 803 can muster to start a motor that size. I'm actually surprised it did it EVER, Even unloaded.
You have either a beast of an 803 or a really easy starting compressor.
Its laid out much like the main forum. There is a section for Aux Equipment. There is a button at the top of the page to take you directly to the classified section.
The 8k and 10k both use the same engine. That fuel burn doesn't suck for an engine that can do over 10kw of power.
At 50% of prime power rating (~5.5kw) the stated fuel burn is 1.7lph. That is less than a MEP802 under the same load conditions.