  1. DieselAddict

    803 Bogs Down and dies at 85% Load

    It was me. Unfortunately I'm thousands of miles from home where the file is located.
  2. DieselAddict

    803 Bogs Down and dies at 85% Load

    Have you checked the voltage between terminal C on L5 and the negative battery terminal when the HOLD circuit is active?
  3. DieselAddict

    DRASH (GETT) Modification Discussion

    No need to get bogged down in theory when you are staring down the barrel of a hurricane. Bring two phases plus a neutral and ground from the generator and connect them as you would any other power source. I recommend looking at the schematic and see which two phases the VR senses from and...
  4. DieselAddict

    Hurricane Florence

    In the spirit of full disclosure I am married to a Chinese woman. She has been wanting to show me around China for a long time. I'm finally taking a real vacation from work to do it. Culture shock is a real thing. Many things that are normal here would not work in the US or Europe. I'm...
  5. DieselAddict

    DRASH (GETT) Modification Discussion

    You are on the right track. Its the phase relationship between the legs that accounts for the difference in voltage on the high voltage side. When two 120v phases are exactly opposite (180 degree out of phase) the math is simple meaning they are additive (technically we would use the same math...
  6. DieselAddict

    DRASH (GETT) Modification Discussion

    Question 1 - Yes you can do that BUT you have to put a 30a overload ahead of anything rated for 30a (wire, connectors, outlets, etc). That means if you want to connect a 30a circuit to your 60a output you need to add a 30a breaker to be safe and compliant. Edit - You'll need to use a 30a 3 phase...
  7. DieselAddict

    Hurricane Florence

    I'm hunkered down in Chengdu China (on vacation) hoping everything is going to be OK for the east coast.
  8. DieselAddict

    803 Bogs Down and dies at 85% Load

    That sounds like what I would do.
  9. DieselAddict

    DRASH (GETT) Modification Discussion

    In my opinion people put too much effort into load balancing these sets when they are being used in emergency situations. As an example are you going to run the dryer much during an outrage? Look at the loads you are most likely to use simultaneously and see if you can spread them around the...
  10. DieselAddict

    DRASH (GETT) Modification Discussion

    Why would you not consider rewiring some of the loads in your panel to make them 3-phase friendly? That could end up being the simpler option.
  11. DieselAddict

    auto shutdown event need help to figure out

    +1 on the overload. You will need every ounce of energy that an 803 can muster to start a motor that size. I'm actually surprised it did it EVER, Even unloaded. You have either a beast of an 803 or a really easy starting compressor.
  12. DieselAddict

    MEP-802/803/831 Generator Control & Parameter Monitor by WIFI Demo

    Looking forward to seeing how this goes. Let me know if I can help.
  13. DieselAddict

    Proper trailer for 802A

    a couple 4x4 posts crossways will be all you need.
  14. DieselAddict

    Looking for Info on a Silencer for MEP03A (OK it's a muffler)....

    Its laid out much like the main forum. There is a section for Aux Equipment. There is a button at the top of the page to take you directly to the classified section.
  15. DieselAddict

    Looking for Info on a Silencer for MEP03A (OK it's a muffler)....

    Good idea but the forum requires posting stuff for sale to be in the classified section. That perk requires a paid membership.
  16. DieselAddict

    Cut MEP-803a fuel return lines

    The new thread button is at the top of the page.
  17. DieselAddict

    Recent MEP Auctions

    The 8k and 10k both use the same engine. That fuel burn doesn't suck for an engine that can do over 10kw of power. At 50% of prime power rating (~5.5kw) the stated fuel burn is 1.7lph. That is less than a MEP802 under the same load conditions.
  18. DieselAddict

    Cut MEP-803a fuel return lines

    Good job and also good thinking about following the manual. I routinely find things assembled incorrectly on units I work on.
  19. DieselAddict

    Drash generator 35kw with 96,000 BTU A/C?

    Roger that. http://www.amphenol-aerospace.com/pdf/12-052.pdf
  20. DieselAddict

    Drash generator 35kw with 96,000 BTU A/C?

    Do you have 3 phase power available at your building?
Top