Going to see if I can repair this thing. The wire was jacked up sideways and twisted between the starter and solenoid which looks to have pulled all the slack out of it. I think that is the root cause of the problem.
The wire looks plenty long to get back on the tab and reach the solenoid...
I'm working on a 831 that needs a starter. I have a couple of parts machines and can pull one if necessary but I was going to see if anyone has a source for one that isn't $350.
I can find the 12v versions of the starter all day for like $60 but the 24v version is stupid expensive.
I get...
Priority parts in my opinion are filters, fluids, and a selection of all the rubber stuff - Belts and hoses. Fuel pump.
fuel leaks are what I find most the common problem on these machines.
if you run the machine a lot then I would recommend having a water pump. They tend to start failing...
As the oil runs its viscosity drops. If you know its going to be days more of running then do an oil change with thicker oil.
More than anything as soon as the critical event is over you need to get to the bottom of the oil pressure problem. Could be something as simple as a partially stuck...
Yea, RVs are horribly inefficient for heating and cooling. I lived full time in a 35' rig while my house was being built and the power consumption of the RV in summer rivaled my 1650 sq/ft house!
Putting diodes in parallel is not good practice. You can have uneven current distribution across the group which can over stress one relative to the others. Its best to use a single higher current diode.
We went through 2 open frame generators here at home during an ice storm that took out power for about 10 days. Engines failed on both. Both brand new.
I've not had one of the military units fail mechanically. I've had them spring fuel leaks but thats the worst that has happened.
One of the...
I think most items that would be affected to the point of concern have gone out of favor (analog radio and TV being ones that come to mind). I know there are concerns with running sensitive medical equipment on low quality power. All I could say is to follow the manufacturers advice with that...
The issue is the modern military units at 15kw and above are 3 phase only. No conversion possible. You have to go back to a MEP004 to get a 15kw unit that can be converted to single phase.
Not really a good fit for a retired military generator.
One option would be to buy 2 of the MEP1040 10kw generators. They can be run in parallel. A pair of those at auction would run $12-$15K
Unless its a 3 phase load, there isn't an option in that power range for a retired military unit in the current gen or one gen back.
If you go back a couple of generations you can pick up a MEP004 (15kw) or MEP005 (30kw) that CAN be converted to single phase. The conversion isn't as simple as...