Search results

  1. R

    Do I have oil pressure?

    Yea it would have destroyed itself with any running with no oil pressure. You can connect a mechanical gauge to the output port on that oil sample valve to confirm that you have decent oil pressure when you open the valve. If thats OK, move it as needed, then fix it with the correct sensor as...
  2. R

    Cleaned M1078A1 Power Distribution Panel (PDP)

    Exactly, voltage isn’t good until tested under load. I feel the same way about CBs in automotive applications. Prefer fuses, but the CBs can be handy when chasing a intermittent overload issue. I kept the best in each size from my panel when I started going thru it and installed fuses…
  3. R

    Cleaned M1078A1 Power Distribution Panel (PDP)

    Yea there is a couple ways to fry the fish. Loading the circuit is definitely a good thing to be able to do….
  4. R

    Cleaned M1078A1 Power Distribution Panel (PDP)

    Mmmm Purty… you will need a voltmeter to see if they are passing voltage:)
  5. R

    Where does this attach?

    “Did I mention it was loud”…:)
  6. R

    CTIS troubleshooting

    The test I described above would be a good next test. Disconnecting line C and applying regulated air directly to the system is another great way to look for system leaks. You said you connected a line and regulator. Did you shutoff the air supply after you pressurized the system? If the...
  7. R

    CTIS troubleshooting

    Yep, they can be a pita. Glued! Morons… He did the manual jumper method I described above and when he went H-B the jumper got hot in his hand, so something is pulling excessive current somewhere. When we last spoke he was working on looking for cross wiring between the solenoid wires To...
  8. R

    CTIS troubleshooting

    That black cover should slide back to expose where the wires are soldered into the pin cups.
  9. R

    CTIS troubleshooting

    That looks like a weak or high resistance electrical/ground connection to the coils of the PCU solenoids. A bad connection will pass full voltage, untill you pull current thru it. On a relay or solenoid coil it sees full voltage, and starts to build a field to pull in the contacts or plug...
  10. R

    M1079 Timing Cover replacement

    A complete set of the military A0 manuals can be found in the manuals section here on steel soldiers. These include the 3116 engine manuals… As mentioned the driveshafts are steep and spin too fast. This in itself makes vibrations, any issues with the shafts make this worse… most of these...
  11. R

    ECO Hubs Who needs 3:07 gears?

    Welcome to the dark side:)
  12. R

    LMTV M1078 All five lights on CTIS solid not flashing.

    yep, pretty sure you can talk to all of them with the correct interface…
  13. R

    CTIS pressure settings increase - no programming, transducer, or module required.

    The filters are on the tire side of the wheel valve, so restriction there would only effect the speed at which the tire inflates or deflates, not valve operation. any restriction would have to be on the truck side of the wheel valve to effect valve operation. Air comes in from the truck and...
  14. R

    ECO Hubs Who needs 3:07 gears?

    It is probably not the transmission. Spinning it at lower RPM would probably cause a little less gear friction heat, but the heat generated is more a factor of the load placed upon the gears, and that is really a factor of the work they are being asked to perform. If the truck is the same...
  15. R

    CTIS pressure settings increase - no programming, transducer, or module required.

    Well the rubber glove test isolates it to just the one wheel valve, and you can add air to the wheel using an air chuck at the wheel schrader valve to see if it is having trouble sealing at higher pressures… but in the end, the vented air must come from a tire thru that wheel valve…
  16. R

    CTIS pressure settings increase - no programming, transducer, or module required.

    Well the quick release valves don't “open” they are pressure regulators. They match the output port(tire side) to whatever pressure is applied on the input(PCU side). it does this by passing air from the input port to the output port if that pressure is greater, or venting output port air to...
  17. R

    LMTV M1078 All five lights on CTIS solid not flashing.

    Sorry, was going to type this, his user name is Plasa...
  18. R

    LMTV M1078 All five lights on CTIS solid not flashing.

    5 solids is an unrecoverable internal fault. You can try hitting it with a hammer, but beyond that it is now a paperweight. Mine was the same, I used 3 switches, a relay and a pressure gauge and control it manually. Search electric over pneumatic manual ctis, also have videos on utube under...
  19. R

    CTIS...soo close to working properly

    I dont think the troubleshooting guide goes as far into it as you have. They the assumw the controller is ok, so they say If 5v from controller is ok, replace the sensor. Was recently helping someone with a failure and worked our way to the pressure sender also...