The burden resistors, R15 and a few other parts are mounted on a metal plate that's inside the control cube. Open the meter panel and lower it down. Then look on the left side of the back wall of the cube. You should see this with the components you are looking for.
(Double click image to...
The board is soldered to the two terminal strips. The round solder pads on the two edges of the board.
That looks to be why the board will not come out. If you have the right solder removal equipment you might be able to unsolder the terminal strips and get the board out. However you risk...
You may need to "exercise" the reconnection switch. The contacts may be oxidized from sitting so long and not making good contact.
Only exercise the switch with the set shut down.
My 802 had crap in there too. I had to repair my radiator because when they drained it they damaged it so I had to tear it down to repair it. With patience and a what seems a zillion bolts you can take the sheet metal apart and get in there. Or you can use a shop vac with a skinny tube, as...
CapePrep,
Your load situation is similar to mine here in Mass.
I've had an 802 for a few years and it has been more than adequate for my needs.
I find I can get by on 1.5 KW to keep the lights on, heat on, fridge running, computers and entertainment center humming along during a storm outage...
Just look to see if there is a fuse holder and fuse to the left side of the A1 Voltage Regulator between A1 and the reconnection switch.
If it's there then you have the fuse mod.
I'd suggest first checking the connections from K8 to the S7 the Battle Short switch.
Check the following with the genset OFF and Battle Short OFF.
K8 terminal 8 should be connected to S7 terminal 6. Check for continuity between these two points. ~ 0 ohms
K8 terminal 7 should be connected to...
After you start to compose a post or reply click on the "Go Advanced" button in the lower right.
You should then see more option buttons at the top of the text entry box.
Click on the one to the right of the two blue globes.
You will then get a dialog box so you can navigate to and upload your...
Pin 2 on DS7 is behaving as it should.
With Battle Short ON this bypasses the Overload section of the K8 relay so it's behaving as if there was an overload detected by K8.
Looks like either an issue with K8, wiring to K8, or wiring and/or components that send signals to K8 such as Burden...
Just from looking at the .xls file here is what the data log seems to be to me.
(I shifted the data so it was all aligned properly first.)
From left to right..
Data Column 1: Voltage Phase A
Data Column 2: Voltage Phase B
Data Column 3: Voltage Phase C
Data Column 4: Current Amps Phase...