  1. csheath

    Hurricane season

    We did the same. I laminated it and hung it by the breaker panel.
  2. csheath

    Aux tanks under 50 gallons

    Since you want to be under 50 gallons and budget isn't a concern you could look at the 32 gallon fuel cells at Summit.
  3. csheath

    Hurricane season

    We were out of power for a week after Hurricane Hermine hit us. That was the last straw for me and began my search for a generator. Having a diesel tractor and backhoe was my inspiration for seeking out a diesel powered generator. Between the two tractors I was already keeping at least 50...
  4. csheath

    Florida Permit/Inspection for MEP installation

    If they wanted you to get a permit they wouldn't make it so difficult. I did my own interlock on the breaker panel. The interlock was made by Square D and sold at the home improvement store. I have had utility workers on my property checking for line damage with my 803 connected and running...
  5. csheath

    My MEP-803a experience

    I'll have to get with you if I ever decide to rivnut my set. I have a small bag of aluminum 10-32 rivnuts but not enough to do the set and no tool. I have found that a dab of antisieze compound will keep the corrosion at bay. Messy but worth it in the long run.
  6. csheath

    MEP-803A Pegs Fuel and Temp Gauges to Right

    I've had the same thing happen on my unit. Cleaning the connectors and messing with the base nut on the studs got both back in operation. Can't say for sure what the cause was but I suspect when you tighten the nuts sometimes it moves the stud in the gauge and causes a problem. I double nutted...
  7. csheath

    Lets talk and over think Coolant

    Used this in my backhoe when I changed it this year. When I did the MEP I used Rotella ELC. Both are rated and recommended for diesel engine so I figured I would be safe. Could not find anywhere on the green Prestone label that it would be okay to use in a diesel. Regular Prestone says it...
  8. csheath

    Mep803a questions

    You should start your own NEW THREAD with the specific problem in the title.
  9. csheath

    Leaf and Rodent Protection for my 803

    The problem I might have if I covered that hole is it could get clogged with leaves and I wouldn't know it.
  10. csheath

    Leaf and Rodent Protection for my 803

    Last sentence in my post was "I still need to cover the large holes on the case with some 1/4" hardware cloth." They are covered now.
  11. csheath

    Leaf and Rodent Protection for my 803

    I originally set my 803 on the ground and it has been sucking leaves up into the engine compartment. Add to that a squirrel has decided it looked like a fun place to store and eat acorns. Fortunately he did not munch on any wires. I was also wanting to drag it out to remove the top and wash the...
  12. csheath

    Picking up an MEP-803A from an Army depot

    Picked mine up in Atlanta with my F150, 6.5 ft bed. Fork lift had no trouble putting it in. Truck drove fine with it in the bed. I winched it out onto a flatbed using 6 ft aluminum ladder type ramps. It didn't slide worth a flip. Had to keep tightening up on the winch and prying up on the skid...
  13. csheath

    Fuel storage and fuel transfer

    If you want to use 55 gallon drums call another diesel supplier to see what their minimum is and if they will pump into drums. You can fabricate a pickup tube. I made a large one for my transfer pump out of PVC. The big hole in a metal drum can use a 2" NPT and the vent hole is 3/4" NPT. I found...
  14. csheath

    Currently Running on MEP Power

    You guys can have that cold weather! Stay safe and warm. Our line trimming crew came through a couple of weeks ago. Wind blew a little the other day and out went the power. We were going out so I didn't bother starting the generator. My monthly test was last Sunday so I got that done and all...
  15. csheath

    Length of pickup tube for bung adapter

    Seeing as how NPT threads are tapered it is supposed to bind as it tightens. It creates a metal to metal seal from the interference of the taper.
  16. csheath

    Length of pickup tube for bung adapter

    Didn't have any issues screwing 1/4" NPT into my bung adapter so wouldn't have suspected it to be BSP. Sorry if I provided mis-information.
  17. csheath

    Length of pickup tube for bung adapter

    In case anyone decides to make their own the thread in the bung adapter is 1/4" NPT. I think I used a piece of 1/2" OD aluminum tube to make the one for my 55 gallon drums. Cut to length and ran a 1/4" NPT tap over one end.
  18. csheath

    Any stateside source for Yanmar rubber grommet/isolators for MEP-831A?

    Pick your needs. https://www.mcmaster.com/rubber-isolators
  19. csheath

    MEP report post Hurricane Michael

    I used Gates fuel hose on mine. Works great and available at O'Reilys. The 1/8" (3.2mm) is part number 27000 and the 1/4" is 27002.