Search results

  1. csheath

    Battery Apology

    I mean when I have the meter on the DC volt setting and connect one lead to the disconnected ground cable and the other lead to the battery post it reads 5 volts. When I do the same test with the meter on the amp scale I get a zero reading. Most vehicles will read a full 12 volt draw due to...
  2. csheath

    Battery Apology

    When I first got my unit I was trying to come up with an inexpensive source for batteries. I settled on the Value Power group 26 from Walmart and for the first 11 months they worked out fine. In December the first set failed a day from being out of warranty. Walmart replaced them and I ran the...
  3. csheath

    Wiring a 50 amp 120v rv service

    You need to use the input built into the RV. That will determine the setting and connection for the generator.
  4. csheath

    Wiring a 50 amp 120v rv service

    Won't it be split in the breaker panel? In a typical home panel you have two sides. 120v uses a single breaker and a 240v uses a double.
  5. csheath

    MEP 831a Hard line cracked

    Can you pull it off and weld it? I have cracked a hard line on my backhoe hydraulics and welded it with success.
  6. csheath

    MEP-80x Fuel Return Line

    Any 1/8" barbed tee should work.
  7. csheath

    Mep-803a interlock setup

    Nice basic setup. If you connect the auxiliary fuel supply you might want to make sure and loosen the vent cap on the drum. Not sure if it would create a vacuum or not. I put some air compressor mufflers on mine to keep them vented all the time. So far I haven't had any condensation problems...
  8. csheath

    Mep-803a oil pressure drop

    TM specifies normal operating pressure as 25-60 psi. I would assume the variable is hot-cold. My unit drops to just over 20 and remains for hours under a 40 amp load. I don't plan to look any further into it.
  9. csheath

    MEP-803a fuel cartridge filters conversion?

    Green Mountain lists a Wix 33472 for a spin on replacement. Not sure if it's supposed to be a direct fit on the original housing or not. They sell it for $29.50 but i see a listing on ebay for much less. My unit indicated all new filters just before it was surplussed. I may never run it enough...
  10. csheath

    803a running @ 130 degrees F after 1 hour+ with no load?

    You don't mention inspecting the thermostat. I put new hoses on mine and did a visual inspection of the thermostat. Mine had a 180 degree thermostat that looks new so I reinstalled it. Running under a 40 amp load my gauge reads right under 180. Shooting the thermostat housing with an IR...
  11. csheath

    803a 24volt draw

    Does it have a solar panel charger? Mine measures 24 volts if I don't disconnect the solar charger.
  12. csheath

    803 Bogs Down and dies at 85% Load

    I am not a generator specialist but from a mechanic point of view I probably would run at 50 percent for 10 hours or so then maybe 75 for another 10. That said, it's probably covered in one of the manuals.
  13. csheath

    803 Bogs Down and dies at 85% Load

    I would NEVER run a "newly rebuilt" engine at 100% load to start with.
  14. csheath

    looking at an 802A with 4000 hours

    Had the vaccine in 2012. Sorry to OP for the highjack. Back to the regularly scheduled program :)
  15. csheath

    looking at an 802A with 4000 hours

    On my 3rd week of shingles here. I wouldn't wish them on anyone.
  16. csheath

    looking at an 802A with 4000 hours

    Pics or it didn't happen!
  17. csheath

    MEP-803A 751-42670/5 Pistons?

    What measurement are you talking about here? If you are referring to end gap then that is too tight. End gaps should be .010" to .020".
  18. csheath

    Need 803 parts, crankshaft bolt.

    If you are not in a hurry I would let it soak and keep trying to turn it every so often. I wouldn't lean on it hard but try to work it in both directions if you can.
  19. csheath

    mep 803 WHY?

    You should buy the Generac.
  20. csheath

    mep 803 WHY?

    Hardy Diesel Generator http://www.hardydiesel.com/diesel-generators/perkins-generator-8-30-kw.html