  1. I

    Generators w/ Slave

    Sounds like a formula for burning out the DC charging system, with luck it is only the somewhat pricey and hard to change (under the fan shroud) DC regulator that is dead. Ike
  2. I

    MEP004A 15 kw Questions

    Simply put they used the same data plate on both the MEP-113a and MEP-004a as amps and volts are the same
  3. I

    MEP002A adventure report plus anyone tied an AC gen to a grid tie inverter as a load?

    Building an improvised load bank for a MEP-002a can be done for under about $50-$60, just go to your local dollar store buy 5 1,500 watt cheap hair dryers (many are really about 1,200 watts), these often sell for under $10 each. (Walmart.com lists one on sale at the moment at $8.40 that claims...
  4. I

    Dont Know What Genset I Have Help Please

    My best suggestion is to try to sell it to your local air craft mechanic
  5. I

    Generators w/ Slave

    It depends on the model and how long you have, most of the smaller 10KW and smaller generators have a fairly minimal charging system, say around 5 amps or so charge rate. The MEP-016D Yanmar retrofits don't have any charging system and the slave port is there for starting only, they also don't...
  6. I

    mep-003a aux fuel

    I think the aux pump runs any time the switch is in the aux run position, but flow is controlled by the solenoid, in the standard run position the aux pump does not run. Ike
  7. I

    Does the MEP-016B have a water separator

    I think it acts a both, but am not sure. Ike
  8. I

    MEP-002A Over Voltage issue, replaced regulator, still there

    While the AVR board is a common cause of this there are a number of other things that can cause this. I recently had a MEP-003a with a similar problem, I eventually tracked it down to a T2 transformer that was installed backwards. Ike
  9. I

    Upgrading my electrical feeds and controls

    Aluminum wire should not be used in high vibration environments due to breakage issues. Ike
  10. I

    Another Mosler GSA file cabinet question

    I am not sure which brand of lock yours has, or how old it is, but I own an older (built in the late 1960's) Mosler Class 2 cabinet, it came with an S&G brand lock. The locks used on all of these GSA containers are radiological attack resistant meaning they have plastic like gears and...
  11. I

    ammeter frequency and voltage gauges

    I personally would be good either way, although the rewiring would have to be more creative if there are 2 amp meters, because as I understand it the amp meter selector switch must ground out connections not in use coming from the CT, not just leave them open so they would be easy to tap from...
  12. I

    MEP-701A Questions

    By the book these generators do not offer a 120/240V single phase operating mode, they offer 120V only or 240V only single phase, although many have been modified, or the design was updated to allow 120/240V operation. Ike p.s. note the technical manuals for this model have lots of mistakes...
  13. I

    mep-002a Brand new head glow plug explodes

    No the manifold heaters are screwed into an electrically isolated plug
  14. I

    ammeter frequency and voltage gauges

    The larger the generator the harder it is balance the small line to neutral 120v connections by moving them from one side to the other, but on a 5KW MEP-002a where a single appliance can amount to 1/4 of its total rated output, it might be as simple as plugging the hair dryer, toaster oven, or...
  15. I

    mep-002a Brand new head glow plug explodes

    How would you wire 2 glow plugs in series given their return circuit is through the negative ground frame? I could see wiring them 12V though through a hybrid 12/24V electrical system much like the CUCV's have. Or wire in an inline resistor which would be wasteful, but relatively easy. On a...
  16. I

    ammeter frequency and voltage gauges

    Since it seems most people use their MEP-002a /003a generators in 120/240V single phase mode, a pair of amp / volt meters operating in amp mode could be nice for load balancing between the two legs at once. Ike
  17. I

    How do you do an initial setup of an MEP-003A

    First confirm you have flow to the injection pump, either hearing return going back into the tank, or loosen the fuel line going into the injection pump and make sure you get flow. Once that is confirmed, you will want to loosen the fuel line going into a diesel injector (avoid putting strain...
  18. I

    ammeter frequency and voltage gauges

    Looking good, one problem I have found with some of the cheaper digital gauges is they tend to have dim displays, so I thought I would ask, is the digital display bright enough to see in full daylight? Ike
  19. I

    MEP-002a / 003a Owner survey?

    Thanks Jerry, but I am not going to worry about it as I am putting a spin on adapter on this one. Ike
  20. I

    MEP-002a / 003a Owner survey?

    The part may have been removed from mine at some point, but I do think my MEP-003a has an older engine installed on it, one clue is the diesel injector holders are marked American Bosch, not Ambac or Yanmar like the newer injectors are. I think American Bosch name was dropped in the late 1970's...