Search results

  1. K

    MEP-831A 120 Volt output Loading?

    When the inverter voltage output switch is set to 120V what is the allowable current loading on L1 & L2 terminals? I understand the max current at 120 volts is spec'd at 31 amps. Can 31 amps be drawn from say L1-L0? Or can L1-L0 only provide 15.5 amps max and L2-L0 only provide 15.5 amps max? I...
  2. K

    Off Topic: Fuel Storage (Hurricane Harvey related)

    Thx for the heads up. Just topped off my diesel and gasoline storage. Heating oil tank just filled too.
  3. K

    MEP 803A Starting Issue at Control Panel

    Do you have TM 9-6115-641-24? It has a Troubleshooting section on "Fails To Crank" that will walk you thru how to troubleshoot the fault.
  4. K

    MEP 803A Starting Issue at Control Panel

    Are you turning the "control switch" (S1) to PRIME/RUN or START? Need to turn it to START to engage the starter. In the PRIME/RUN position the fuel pump is energized and makes a clicking sound.
  5. K

    Auction Question

    So far so good with the two 831's I got from Chambersburg last week. Both Tier 2 resets with 2 hrs each. Only issue with one was a stuck No Fuel float. A couple of minutes with a length of wire thru the fuel filler and it was un-stuck. Just had to charge the batteries and add fuel. Both ran...
  6. K

    Finally joined the MEP-803A club...

    Yes - That is the Fuse Mod. It protects your Quad winding from burning up should the Regulator's internal diode bridge short out. The MOV mod is intended to protect the Regulator's internal diode bridge from shorting out. If you need a MOV for the mod just PM me and I'll mail you one.
  7. K

    Chambersburg directions

    Be sure to stop and get your background check BEFORE going to the DRMO building. Budget about 15 minutes for the check. It's at the corner of Wisconsin Ave and Advantage Ave. Advantage is your second left after heading in on Coffey Ave from 997.
  8. K

    GLA Invoice

    Yup - just got mine and was able to print it out before I leave. Phew....
  9. K

    GLA Invoice

    Thx for the feedback. I may have to come up with plan B to get the invoice printed. Hitting the road tomorrow morning for PA for a pre-planned camping trip.
  10. K

    GLA Invoice

    A GLA auction closed yesterday at 4:00 PM. Won a couple of gen sets. :-D Credit card already on GLA system for payment. When does the Invoice usually become available on-line for downloading after a auction closes?
  11. K

    Mep 004a and 005a "carrier bearing"

    Look at TM9-6115-464-24P for the 004A July 1992 edition. See figure 41. I believe the bearing is a 6307-2-RS. A quick Google shows many suppliers of the bearing.
  12. K

    MEP804B - no start

    Manuals... https://greenmountaingenerators.com/manuals-and-support/mep-804a-mep804b-mep814a-mep814b-manuals/ Here is the list of manuals Guyfang put together for the 804B MEP-804B 15 KW LO 9-6115-643-12 MEP-804B 15 KW TB 9-6115-643-13 MEP-804B 15 KW 4TNV84T-DFM TM 9-2815-538-24&P...
  13. K

    Finally bought a MEP-831a

    Ah... Didn't know about that tidbit in the TM.
  14. K

    Finally bought a MEP-831a

    True for conventional generators like the 002, 802, etc but the 831 is an inverter generator. Frequency is maintained by the 831's inverter.
  15. K

    Need to replace diodes on armature of mep002a

    Found this from an older SS post... Cross Reference: #27 NSN...5961-01-050-7048... 1N1204RA Semiconductor Device, Diode #28 NSN...5961-01-054-4151... 1N1204A Semiconductor Device, Diode Both in stock at Allied. About $3 each http://www.alliedelec.com/vishay-pcs-vs-1n1204a/70078679/...
  16. K

    Need to replace diodes on armature of mep002a

    Part numbers are available in the TM's Look at the -24P TM for part numbers. https://www.steelsoldiers.com/showthread.php?155935-All-the-TM-s-you-need-to-work-on-the-MEP-002A
  17. K

    Running mep802/3 with out batteries

    From the -10 TM Two batteries are required, one on each side of the generator set. The batteries are electrolyte serviceable, lead acid, 12 volt type, connected in series. After starting, the generator set is capable of operating with batteries removed. A diode and a fuse, located behind the...
  18. K

    MEP803A heater

    The nine 803's in the last GL auction in NY went for and average of $1,796.
  19. K

    PU-239E/G need help finding TMs, more information

    You can download a copy of TM 5-6115-365-15 dated May 1966 from here: http://www.liberatedmanuals.com/search.mpl?q=5-6115-365-15&Search=Search Right click of the manual and then do a Save AS...
  20. K

    MEP-803A 1 deg F / -17c cold start test and video

    Looks like your first attempt and starting failed due to not holding it in the START position long enough for the oil pressure to build up. I noticed the Low Oil Pressure light was on when it stalled out and your oil pressure gauge was virtually at zero. Probably would have kept running if...
Top